Field Service Technician, Electrical Testing in Minneapolis, Minnesota at Premise INC
Job Description
Position Summary
Premise Inc. is seeking an experienced Field Service Technician, Electrical Testing to perform electrical testing, inspection, troubleshooting, and commissioning activities on utility-scale solar farms, battery energy storage systems, transformers, switchgear, and associated low- and medium-voltage electrical systems.
This position will independently plan and execute testing activities, configure and operate test equipment, interpret test results, troubleshoot failures, recommend corrective actions, and prepare complete testing and turnover documentation.
During the first 6–12 months, approximately 50%–70% of the position’s workload will focus on electrical testing, commissioning, and QA/QC activities, with approximately 30% dedicated to troubleshooting and operations and maintenance support. When testing work is not scheduled, the technician will assist with switchgear and transformer terminations and other technical field-service needs consistent with the employee’s qualifications and applicable licensing requirements.
Essential Duties and Responsibilities
- Develop and execute electrical testing plans based on project specifications, customer requirements, equipment documentation, and applicable standards.
- Select, configure, and safely operate the appropriate test equipment for each assignment.
- Perform primary-injection testing on electrical equipment and systems.
- Perform transformer testing, including:
- Turns ratio testing
- Insulation-resistance testing
- Winding-resistance testing
- Power-factor and Doble testing
- Inspect and test switchgear, circuit breakers, instrument transformers, and related power-distribution equipment.
- Perform protective-relay testing, calibration, functional testing, and settings verification.
- Interpret test data and identify abnormal results, failures, or deficiencies.
- Troubleshoot failures, recommend corrective actions, and perform retesting to confirm successful resolution.
- Support the acceptance testing and commissioning of low- and medium-voltage electrical systems.
- Perform or support VLF cable testing, tan delta testing, hipot testing, grounding-system testing, and related diagnostic activities based on experience and project requirements.
- Support equipment energization, startup, and commissioning activities.
- Review one-line diagrams, electrical schematics, construction drawings, equipment submittals, project specifications, and customer closeout requirements.
- Prepare complete, accurate, and timely test reports, turnover packages, deficiency logs, and corrective-action records.
- Complete customer-specific forms, templates, and testing documentation for each project.
- Coordinate testing schedules, outage windows, site access, and energization-readiness activities with site superintendents, project managers, QA/QC personnel, engineers, vendors, and customers.
- Provide technical support for QA/QC, troubleshooting, operations and maintenance, field service, and project-closeout activities as workload requires.
- Assist with switchgear and transformer terminations when testing work is not scheduled and when permitted by the employee’s qualifications and applicable licensing requirements.
- Maintain test instruments, equipment records, and required calibration documentation.
- Follow approved procedures and all applicable electrical-safety, arc-flash, lockout/tagout, and project-specific requirements.
Required Qualifications
- Three or more years of hands-on experience in electrical testing, commissioning, power-system field service, or industrial electrical maintenance.
- Demonstrated experience working with medium-voltage electrical systems and equipment.
- Hands-on experience performing primary-injection testing.
- Hands-on transformer-testing experience, including:
- Turns ratio testing
- Insulation-resistance testing
- Winding-resistance testing
- Power-factor or Doble testing
- Experience testing and inspecting switchgear and circuit breakers.
- Experience with protective-relay testing, calibration, functional testing, or settings verification.
- Ability to independently:
- Develop a testing plan
- Select and configure testing equipment
- Execute the required tests
- Interpret test results
- Troubleshoot failures
- Recommend corrective actions
- Complete final testing reports
- Ability to interpret test data and identify equipment deficiencies or abnormal results.
- Ability to read and apply one-line diagrams, schematics, construction drawings, equipment manuals, project specifications, and test procedures.
- Ability to produce accurate test reports and turnover documentation using project-specific forms and customer requirements.
- Working knowledge of NFPA 70E electrical-safety practices, energized-work controls, arc-flash boundaries, and lockout/tagout procedures.
- Proficiency with common electrical test instruments, including Megger, Doble, Omicron, or equivalent equipment.
- Ability to use Microsoft Excel and electronic systems to enter test data, organize results, and prepare reports.
- Valid driver’s license and ability to travel to active project sites.
- Ability to work independently in the field while communicating effectively with construction, engineering, QA/QC, operations and maintenance, and project-management teams.
Preferred Qualifications
- NETA Level II or III certification or comparable hands-on electrical field-testing experience.
- A current electrical license issued by Minnesota, Illinois, Wisconsin, or another state.
- Experience performing VLF cable testing.
- Experience with tan delta and hipot testing.
- Experience performing grounding-system testing.
- Experience working with 5 kV, 15 kV, 25 kV, 34.5 kV, or 35 kV electrical systems.
- Experience in utility-scale solar, BESS, substations, wind energy, utilities, industrial facilities, data centers, or another comparable power-distribution environment.
- Experience with SEL, GE, Schneider Electric, or comparable protective-relay and control systems.
- Experience with PowerDB, relay-testing software, manufacturer-specific test-set software, or other electronic reporting platforms.
- Associate degree in Electrical Power and Controls, Electrical Technology, or a related discipline. Relevant military power-generation or electrical training may substitute.
- OSHA 10 or OSHA 30 certification.
- Current NFPA 70E training.
- CPR and First Aid certification.
- Experience leading field-testing activities or coordinating equipment-energization readiness.
Training and Onboarding
The successful candidate may receive training in the following areas:
- Equipment energization and Premise commissioning processes
- Customer-specific test reports, forms, and closeout templates
- Project-specific software and reporting systems
- Premise testing and documentation standards
- Customer- and project-specific operating procedures
Prior knowledge of every customer form, software platform, or manufacturer-specific program is not required. The technician must be able to learn and accurately complete the documentation required for each project.
Premise will establish standard operating procedures for testing, reporting, quality control, and project turnover. Previous experience with PowerDB or similar platforms is beneficial but is not a prerequisite for consideration.
Service Area and Travel Requirements
This position will initially support projects in Illinois and Minnesota.
The technician should expect to:
- Participate in Premise’s established field-travel rotation.
- Travel between Illinois, Minnesota, and other assigned project locations.
- Stay overnight when required by project schedules.
- Work overtime during testing, commissioning, outage, or project-closeout periods.
- Support planned outage work.
- Operate a company or assigned vehicle, when authorized.
- Transport testing equipment and project materials as assigned.
- Travel outside the Midwest as Premise’s testing and field-service operations expand.
Emergency-call responsibilities are not anticipated when the position begins but may be introduced as Premise expands the service offering and begins supporting additional customers.
Work Environment and Physical Requirements
Work is performed primarily at active construction sites and operating facilities, often outdoors in varying weather conditions and around energized or potentially energized electrical equipment.
The position requires regular standing and walking on uneven terrain, climbing, bending, and working near electrical enclosures. The employee must be able to lift and carry up to 50 pounds with or without reasonable accommodation.
Extended hours, early starts, weekends, outage windows, and overnight travel may be required during testing and commissioning periods.
Scan to Apply
Just scan this QR code to apply from your phone.
- Fast
- Easy
- Apply on the go